top of page

How Do You Prevent Shear During Patient Transfers?

Writer: Pressure Sore Recovery
Pressure Sore Recovery
4 days ago
9 min read

Quick Summary

To prevent shear during patient transfers, move the person with the surface rather than across it: use a slide sheet or slide board, keep neutral alignment through hips, knees and spine, and move on a coordinated count with enough helpers. Avoid dragging or pulling anyone up by the shoulders, and check skin and positioning straight after every transfer.

  • Shear strains deeper tissue around the sacrum, buttocks and ischial tuberosities while skin may still look intact.

  • Position slings flat and centred with seams flat, and check the person is fully supported before any lift.

  • Slide sheets lower surface friction but do not remove shear inside the body.

  • Check for redness that does not fade, discolouration, warmth, swelling and texture changes after every transfer.

  • Ask for professional assessment for spinal cord injuries, fragile skin or existing pressure ulcers.

Still getting red marks after transfers?

A patient-led PDF on protecting skin and preventing pressure damage, from lived experience.

Table of Contents

I'm Not a Doctor, I'm the Patient.

Last Updated: 16 November 2026

I'm not a doctor. I'm the patient. This article combines published information with lessons from my own experience of living with serious pressure sores. It is intended to help you understand the subject and ask better questions of your healthcare team, not replace professional medical advice.

What Is the Difference Between Friction and Shear in Pressure Ulcers?

Friction is the rubbing force on the skin's surface.

Diagram showing how pressure, friction and internal tissue sliding differ to help prevent shear.

Pressure, friction and shear are three different forces. They often act together during a transfer.

  • Pressure squeezes tissue between a bone and a surface, such as a mattress or chair.

  • Friction happens when skin drags across a sheet, slide board or sling.

  • Shear happens when surface layers move while deeper layers stay fixed.

That difference matters. Shear can strain deeper tissue around the sacrum, buttocks and ischial tuberosities. Moisture can also change how these forces affect the skin, which is worth understanding alongside friction and shear.

The NHS information on pressure ulcers explains that pressure and shear both contribute to pressure damage. The NICE guidance on pressure ulcers stresses risk assessment and skin inspection for anyone at risk.

Where Shear Does the Most Damage: Sacrum, Buttocks and Ischial Tuberosities

Shear does its worst work where bone sits close to the skin.

When you slide down a bed or shuffle forward in a chair, skin stays in contact with the surface. Deeper tissue shifts underneath it.

This is why a red mark is not the whole story.

Healed Doesn't Mean Fixed. Once tissue has been damaged, that area can stay vulnerable. A healed sore is not a licence to stop protecting the skin.

Safe Patient Transfer Techniques for Bed-to-Wheelchair and Hoist Transfers

Safe patient transfer technique comes down to one principle: move the person with the surface, not across it. Reduce drag, keep alignment neutral, and never pull a body sideways over a sheet.

A shear-focused transfer sequence

Use this sequence for bed-to-wheelchair, hoist and slide-board transfers. It is a framework, not a guarantee, and your tissue viability nurse or physiotherapist may adapt it.

  1. Assess before you move. Check skin condition, pain, mobility, cognition, body size and any existing pressure ulcer. A person with a spinal cord injury, fragile skin or an existing sore needs a plan agreed with their team, not a generic technique.

  2. Choose the aid for the transfer type and ability. A slide board suits a person who can assist; a hoist suits someone who cannot weight-bear; air-assisted devices suit heavier or more dependent transfers. Match the aid to the person, not the other way round.

  3. Set the environment. Lower the bed, raise the chair so surfaces are close in height, lock brakes, remove or fold away the armrest, and clear the path.

  4. Position the sling or slide sheet flat and centred. Seams flat, no ruts or folds, and the person fully supported before any lift.

  5. Keep neutral alignment through hips, knees and spine. Avoid twisting the torso or letting the hips lag behind the shoulders.

  6. Move on a coordinated count with enough helpers. A sudden pull creates shear; a smooth, counted move reduces it.

  7. Check positioning and skin straight after the transfer. The transfer is not finished when the person lands in the chair.

Bed-to-wheelchair transfers

Position the wheelchair at a slight angle to the bed, lock the brakes and use a slide board or slide sheet so the person moves over a smooth surface.

Watch out: dragging a person up the bed by the shoulders or under the arms pulls skin one way and tissue the other. It is one of the clearer routes to shear.

Hoist transfers

Sling positioning is everything. A sling that sits too low or rides up can create shear as the body settles into it. Check that the sling is centred, seams are flat, and the person is fully supported before lifting. Preparation protocols and sling choices vary by centre, wound and patient, so follow your local manual-handling policy.

When someone slides down in bed or a chair

This is a common scenario that many guides skip. Sliding down is shear in action: skin stays in contact while deeper tissue shifts. Reposition early rather than waiting until the person has slipped far. Adjust the bed angle, use a slide sheet and enough helpers, and avoid pulling the person back up by the shoulders. If sliding down keeps happening, the seat or mattress angle, cushion or positioning may need review by the team.

Patient-specific risk assessment

Mobility, skin condition, pain, cognition, body size and existing pressure injuries all change the transfer plan. If you use a wheelchair day to day, our guide to wheelchair user skin protection covers what I learned about protecting skin between transfers.

Equipment that reduces friction does not necessarily eliminate internal shear. A slide board or hoist can still let tissue shift if the person is not well positioned or supported.

How Slide Sheets for Patient Repositioning Reduce Drag

Slide sheets for patient repositioning cut friction by giving skin a low-resistance surface to travel over. They reduce the drag on the skin, but they do not remove shear inside the body. That distinction is important: a slide sheet makes the move easier and kinder to skin, but it does not cancel the internal forces created when tissue shifts. (Source: NICE guidance on pressure ulcers)

Choosing the right transfer aid

A decision guide makes equipment advice more actionable. This is a starting point, not a prescription, and your manual-handling team should confirm what is safe for the individual.

Aid

Best suited to

Shear consideration

Slide sheet

Repositioning in bed, sliding up or down

Lowers surface friction; internal shear still depends on positioning and movement

Slide board

Bed-to-wheelchair transfers for people who can assist

Tissue can still shift if alignment is poor or the move is rushed

Hoist

People who cannot weight-bear or assist

Sling fit and centring matter more than friction

Air-assisted device

Heavier or more dependent transfers

Reduces drag but does not eliminate internal shear

Using slide sheets well

  • Place the sheet under the person before the move, not during it.

  • Keep the sheet flat and free of ruts or folds.

  • Use enough helpers so no one has to yank or tug.

  • Move in one smooth motion on a count.

  • Remove the sheet afterwards so it does not bunch under the body.

Watch out: treating a slide sheet as a cure-all. It lowers friction at the surface, but shear inside the body still depends on how the person is positioned and moved.

When someone slides down in bed

Sliding down is a common shear scenario. Reposition early, adjust the bed angle, use a slide sheet and enough helpers, and avoid pulling the person back up by the shoulders. If it keeps happening, ask the team to review the mattress, cushion or positioning.

If you are building a kit of transfer equipment, you can browse support equipment for sore prevention to see the tools that help reduce friction and drag.

Early Signs of Pressure Injury to Check After Every Transfer

Early signs of pressure injury are easy to miss if you only look for broken skin.

Do your check the same way each time:

  • Look at the sacrum, buttocks, heels and ischial areas.

  • Press the area gently and see whether redness blanches or stays.

  • Feel for warmth, swelling or firmness compared with nearby skin.

  • Note any change in colour, especially darker or purplish patches.

  • Record what you find and when.

Deeper tissue damage can be present before the surface breaks. That is why a mark that will not fade deserves a professional look, not a wait-and-see approach.

Our article on the early signs of skin breakdown goes deeper into what to watch for and when to raise it with your team.

Individualising Transfer Technique and Knowing When to Ask for Help

No single transfer technique suits everyone. Spinal cord injury, fragile skin, existing pressure ulcers, body shape and strength all change what is safe.

Equipment that reduces friction does not necessarily eliminate internal shear.

Ask for help when:

  • The person cannot bear weight or assist with the move.

  • Skin is already damaged or healing.

  • You are transferring alone and struggling.

  • The person is heavier than you can safely manage.

  • Anything feels unsafe or rushed.

Carers get hurt too. If you support someone at home, our pressure sore management guide for caregivers covers practical day-to-day care and when to call in help.

Practical Steps to Prevent Shear During Patient Transfers

The practical steps to prevent shear during patient transfers are simple to list and easy to forget under pressure.

  • Assess the person's skin and risk before the transfer.

  • Choose the right aid for the transfer type and ability.

  • Set bed and chair height, lock brakes, clear the path.

  • Position the sling or slide sheet flat and centred.

  • Keep neutral alignment through hips, knees and spine.

  • Use enough helpers and move on a coordinated count.

  • Avoid dragging, pulling or sudden shifts.

  • Check positioning and skin straight after the transfer.

  • Record any redness, warmth or swelling.

Transfer type

Main shear risk

Practical fix

Bed to wheelchair

Dragging across the gap

Slide board, matched heights, brakes on

Hoist transfer

Sling riding up or sitting low

Centre the sling, flatten seams, check support

Repositioning in bed

Pulling up by shoulders

Slide sheet, enough helpers, smooth move

Sliding down in bed

Skin drags as body slips

Reposition early, adjust bed angle

Slide board transfer

Tissue shift despite low friction

Neutral alignment, steady coordinated move

A common mistake is treating a slide sheet as a cure-all.

What most guides miss is the follow-up. The transfer is not finished when the person lands in the chair.

Healed Doesn't Mean Fixed. Prevention is lifelong, not a course you complete.

Preventing shear is a skill you build, and it is one worth building.

Frequently Asked Questions

How can shearing be prevented during patient transfers?

The main steps are to avoid dragging and pulling, use a slide sheet or hoist sling correctly, keep the bed at a safe working height with brakes on, and make sure enough people are helping. Keep the head of the bed as flat as the person can tolerate during moves, and check positioning and skin afterwards. No single technique guarantees prevention, which is why technique should be assessed for each person by their moving and handling team.

Can a slide sheet prevent shear during a patient transfer?

A slide sheet reduces friction between the person and the surface, which lowers the effort needed and cuts dragging. It does not eliminate internal shear forces, because tissue layers can still slide against each other under load. Use slide sheets as one part of safe patient handling, alongside correct sling choice, adequate assistance and post-transfer skin checks, rather than treating them as a complete solution.

What is the difference between pressure, friction and shear?

Pressure is direct compression of tissue between a bony prominence and a surface. Friction is resistance at the skin surface when it drags across a sheet or surface. Shear is internal: layers of tissue slide against each other, which can damage deeper tissue around the sacrum, buttocks and ischial tuberosities. Deeper damage may develop before any visible skin breakdown appears, so persistent redness or discolouration after a transfer needs professional assessment.

How can carers check for early signs of skin damage after a transfer?

Look for persistent redness or discolouration that does not fade, warmth, swelling, blistering or changes in skin texture over bony areas. Check the sacrum, buttocks, ischial tuberosities, heels and any area that took load during the move. Record what you see and report it to the wound-care team. Healed Doesn't Mean Fixed: previously damaged skin stays vulnerable, so keep checking after every transfer and repositioning.

 
 
 

Comments


bottom of page